Leave Your Message
China CAATM GTYQ-CA228F Point-type Combustible Gas Detector - Factory Supplier for Safety in Various Applications
Hot Products
Products Categories
Featured Products

China CAATM GTYQ-CA228F Point-type Combustible Gas Detector - Factory Supplier for Safety in Various Applications

Applicable Locations
Business Setup:
- Liquefied Gas Stations in China: Essential for monitoring gas levels and ensuring safety, particularly for suppliers looking to enhance safety measures.
- Gas Boilers: Critical for maintaining safe operations and preventing leaks in industrial factories across various sectors.
- Restaurants: Very important for kitchen safety and ensuring compliance with health regulations, making them a priority for suppliers in the food industry.
- Other Natural Gas Utilization Areas: Including various locations where natural gas is routinely used, emphasizing the need for reliable monitoring solutions.
Industrial Environment:
- Petroleum and Chemical Industry: Necessary for monitoring gas emissions and ensuring worker safety, highlighting the role of suppliers in providing reliable equipment.
- Oil Storage Facilities: Crucial for leak detection and environmental protection, especially for factories handling large volumes of gas.
- Automotive Manufacturing: Safety is paramount for production processes that involve gases, implicating the need for quality products from trusted suppliers in China.
- Pharmaceutical and Steel Industry: Essential for monitoring hazardous gases, underscoring the importance of advanced technology from factories specializing in gas detection.
- Shipbuilding and Other Locations: Areas where flammable, toxic, or hazardous gases may be present require robust monitoring systems, making our solutions vital for industry suppliers.

    Main Features

    Reliable Performance
    Ensures consistent operation and durability.
    High Sensitivity
    Able to detect even minute concentrations of gases.
    Extended Service Life
    Designed for extended service life and reduced maintenance.
    Powerful Anti-Interference
    Minimize interference from external factors.
    Reduced Measurement Errors
    Provides accurate readings for increased safety.
    Live Display
    Provides instant visibility of gas concentration levels.

    Product Description

    This product has the characteristics of fast response time, high measurement accuracy, good stability and good repeatability. It is user-friendly and able to withstand harsh environmental conditions. The core component adopts a world-renowned brand gas sensor, which has strong gas sensitivity, good repeatability and fast response speed. They are designed to be easy to use and maintain. To sum up, the CA228F has high stability, excellent accuracy and advanced intelligence.

    In addition, CA228F is made of high-strength materials and is resistant to pressure, falling, wear and corrosion, providing excellent protective performance. The equipment is splash-proof, dust-proof and explosion-proof. Its explosion-proof capabilities have been evaluated by the nationally designated explosion-proof product inspection center and obtained the national explosion-proof certificate.

    CA228F can be connected to a host (such as CA2100D) whose RS485 signal is electrically isolated to ensure safer communication. The detector transmits sampled values by controlling the voltage, manages the standard 4-20mA current signal or converts it into an RS485 digital signal through the serial port, and then uploads it to the host for display.

    This product supports customized detection of a variety of gases, including oxygen, hydrogen sulfide, carbon monoxide, chlorine, ammonia, etc. It can also be customized to include audible and visual alarm functions. When the gas concentration reaches the specified threshold, the device will emit an alarm sound of at least 70 decibels so that the user can respond and take action in time.

    Compared with the basic CA228, the CA228F has a real-time gas concentration display function. What’s more, this product can be directly integrated with our innovative IoT platform through NB-IoT technology, getting rid of the traditional alarm controller configuration and significantly reducing equipment purchase costs. In addition, the IoT platform is designed using the configuration UI mode, which allows for platform adjustment, product operation and maintenance, large-screen customized output, report generation, etc. without coding or hiring professional IT personnel. Ordinary employees can learn to operate it quickly. Additionally, the entire IoT platform can be deployed directly on your servers, making your digital transformation more seamless.

    Technical Parameters

    Detection Principle Sampling Method Measuring Range Alarm Error Response Time
    Catalytic combustion Free diffusion 3%LEL~100%LEL ±3%LEL <=30s
    Working Voltage Power Consumption Signal Transmission Distance Operating Temperature Dimension
    DC12V~DC30V <=2W 1200m -40°C~70°C 148x150x85(mm)

    Frequently Asked Questions

    What are the primary differences between the CA228F and the basic CA228 model?
    Unlike the basic CA228, the CA228F features a real-time gas concentration display. Additionally, it supports direct integration with our innovative IoT platform via NB-IoT technology, eliminating the need for traditional alarm controllers and lowering purchase costs.
    Which gases can the CA228F gas detector monitor?
    The CA228F supports customized detection for a wide variety of gases, including but not limited to oxygen, hydrogen sulfide, carbon monoxide, chlorine, and ammonia.
    Does the CA228F include built-in alarms?
    Yes, the device can be customized to include both audible and visual alarm functions. When gas levels exceed the safety threshold, it sounds an alarm of at least 70 decibels to alert nearby personnel.
    Is the CA228F suitable for harsh industrial environments?
    Absolutely. The CA228F is built from high-strength materials resistant to pressure, drops, wear, and corrosion. It is also certified splash-proof, dust-proof, and explosion-proof by the national inspection center.
    How does the detector transmit data to the host system?
    It manages standard 4-20mA current signals or converts them into RS485 digital signals through the serial port, uploading the data to a compatible host (such as the CA2100D) for display.
    What are the power and wiring requirements for installation?
    The CA228F operates on a working voltage of DC12V to DC30V with a low power consumption of <=2W. It supports a long signal transmission distance of up to 1200 meters.