Leave Your Message
High Sensitivity Ozone O3 Gas Leak Detector - CAATM GTYQ-CA228 for Commercial & Industrial Use | China Suppliers & Factory
Hot Products
Products Categories
Featured Products

High Sensitivity Ozone O3 Gas Leak Detector - CAATM GTYQ-CA228 for Commercial & Industrial Use | China Suppliers & Factory

Ideal Applications
Our gas detection solutions are perfect for a variety of environments. In commercial settings, they are designed for use in liquefied gas stations, gas boilers, restaurants, villas, basements, and any other areas where gas is utilized. In industrial sectors, these devices are essential for the petrochemical industry, oil depots, automobile shipbuilding, and more.

High-Quality Sensors
Equipped with advanced sensors, our products guarantee stable performance, exceptional sensitivity, and an extended service life. With strong anti-interference capabilities, these sensors ensure minimal measurement errors and provide real-time data display. Our factory in China is committed to delivering reliable gas detection solutions, making us a trusted supplier in the industry.

    Product description

    The product features a fast response speed, high measurement accuracy, good stability and repeatability, simple operation, and the ability to withstand harsh environmental conditions. The core components utilize gas sensors from world-renowned brands, offering excellent gas sensitivity and outstanding repeatability, with quick response times and ease of use and maintenance. In summary, the CA228 boasts high stability, high precision, and high intelligence.
    8-探头系列:CA228
    Robust Protection & Certification
    The CA228 is made from high-strength materials, providing characteristics such as pressure resistance, drop resistance, wear resistance, and corrosion resistance, ensuring a higher level of protection. The device is equipped with splash-proof, dust-proof, and explosion-proof functions. Its explosion-proof performance has been tested and certified by a national designated explosion-proof product testing center, and it has obtained a national explosion-proof qualification certificate.
    Flexible Output & Target Gases
    The CA228 can be connected to a host (such as the CA2100D) and features RS485 signal electrical isolation to ensure safer communication. The detector samples values by controlling voltage output to regulate a standard 4-20mA current signal, or it can convert this into an RS485 digital signal via a serial port for display on the host. In addition to detecting ozone, the product can be customized to detect hundreds of gases according to customer needs, such as oxygen, hydrogen sulfide, carbon monoxide, chlorine, ammonia, and more.
    Alarm & Product Variations
    An audible and visual alarm function can also be customized. When the gas concentration reaches a set value, the device emits an alarm sound of at least 70 decibels, facilitating quick user response and handling. The CA228 is a basic product; for models with features like real-time display, the CA228F or CA228-D can be recommended.
    NB-IoT & Intelligent Cloud Platform
    More importantly, this product can directly connect to our innovative IoT platform via NB-IOT technology, eliminating the traditional layout of alarm controllers and significantly reducing equipment procurement costs. Furthermore, the IoT platform is built using a configuration UI model, allowing for platform adjustments, product operation and maintenance, large screen custom output, and report generation without the need for coding or hiring professional IT personnel, enabling ordinary employees to quickly get started. Additionally, the entire IoT platform can be directly deployed on your server, making your digital transformation more fearless.

    Technical Parameters

    Parameter Specification Parameter Specification
    Detection principle Catalytic combustion Working voltage DC12V~DC30V
    Sampling Method Free diffusion Power Consumption <=2W
    Measuring range 3%LEL~100%LEL Signal transmission distance 1200m
    Alarm error ±3%LEL Operating temperature -40°C~70°C
    Response time <=30s Dimension 148x150x85(mm)

    Frequently Asked Questions

    What gases can the CA228 detector detect?
    In addition to ozone, the CA228 can be customized to detect hundreds of gases according to customer needs, including oxygen, hydrogen sulfide, carbon monoxide, chlorine, ammonia, and more.
    What signal output and communication options are supported?
    The detector samples values by controlling voltage output to regulate a standard 4-20mA current signal, or it can convert this into an RS485 digital signal via a serial port for display on a host (such as the CA2100D). It also features RS485 electrical isolation for enhanced communication safety.
    Is the CA228 certified for harsh and hazardous environments?
    Yes. The device is built from high-strength materials offering pressure, drop, wear, and corrosion resistance. It features splash-proof, dust-proof, and explosion-proof capabilities, tested and certified by a national designated explosion-proof product testing center.
    How does the IoT functionality help reduce deployment costs?
    The device connects directly to an IoT platform via NB-IoT technology, removing the need for traditional alarm controllers. The platform uses a configuration UI model that enables maintenance, reports, and screen outputs without coding, and it can be deployed directly on private servers.
    What are the differences between the CA228 and other series models?
    The CA228 serves as the core base model. If real-time on-device display is required, the CA228F or CA228-D models are recommended.
    Does the detector support on-site audible and visual alarms?
    Yes, an audible and visual alarm can be customized. Once target gas levels reach the configured threshold, the unit sounds an alarm of at least 70 decibels to enable quick personnel response.